SAM-e
Installation and
Operation Manual
Includes installation, operation
maintenance and troubleshooting
information for your SAM-e and Mini
SAM-e Short Absorption Manifold.
1507619-H| 10 SEP 2014
Important: Read and save these instructions. This guide to be left with equipment.
Page view 0
1 2 3 4 5 6 ... 61 62

Summary of Contents

Page 1 - Operation Manual

SAM-e Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information for your SAM-e and Mini

Page 2 - SERIAL #

7 | Installation SAM-e In-Duct

Page 3 - Contents

SAM-e Installation | 8 Typical SAM-e Installation General SAM-e Assembly Diagram

Page 4 - 1

9 | SAM-e Installation 1 Fasten support brackets to header using 5/16” washers and 5/16” nylon lock-nuts. 2 Place header on duct floor and

Page 5 - Introduction

SAM-e Installation | 10 3 Insert tube into insertion stop washer and then into grommet. Wetting grommet with water will make assembly easier. E

Page 6 - Identify your Components

11 | SAM-e Installation 5 Attach tube support bracket using supplied 1/4” lock-washer and 1/4” hex screws. 6 No mounting frame – proceed t

Page 7 - SAM-e Installation

SAM-e Installation | 12 6A If no mounting frame is supplied: Attach bracket flanges to tube support bracket using 5/16” screws, washers, and nylon

Page 8 - How to Use this Manual

13 | SAM-e Installation 7 Slide frame sides into frame base. 8 Attach Frame Pivot using 5/16” bolt, washer, and nylon lock-nut. Side V

Page 9 - SAM-e Installation

SAM-e Installation | 14

Page 10 - SAM-e In-Duct

15 | SAM-e Installation Installation in Vertical Duct

Page 11 - Typical SAM-e Installation

SAM-e Installation | 16 1 Complete assembly following Steps 1 through 8 on pages 9 through 13. Install complete assembly into duct at 10° angl

Page 12 - 9

Thank you for choosing Nortec. Proprietary Notice This document and the information disclosed herein are proprietary

Page 13 - SAM-e Installation

17 | SAM-e Installation Mini SAM-e Installation Procedures

Page 14 - 11

SAM-e Installation | 18 Mini SAM-e Assembly General Installation

Page 15 - SAM-e Installation

19 | SAM-e Installation 1 Place header into duct. Use supplied template to cut holes for steam and condensate parts. Attach header to duct using

Page 16 - 13

SAM-e Installation | 20

Page 17 - SAM-e Installation

21 | SAM-e Installation Plumbing

Page 18 - Vertical Duct

SAM-e Installation | 22 SAM-e with Pressure Steam Pressurized Plumbing with External Separator • Steam components in grey provided by Nortec. • T

Page 19 - SAM-e Installation

23 | SAM-e Installation Pressurized Plumbing without External Separator Note: The SAM-e header functions as a steam separator, therefore an ext

Page 20 - Installation Procedures

SAM-e Installation | 24 Internal Baffle Plate

Page 21 - SAM-e Installation

25 | SAM-e Installation Condensate Pump Plumbing When pressurized steam enters SAM-e, pressure drops down to almost atmospheric p

Page 22 - 19

SAM-e Installation | 26 Mini SAM-e with Pressurized Steam Mini SAM-e Pressurized with External Separator • Steam components in grey provided by

Page 23 - SAM-e Installation

Contents 2 Introduction 2 Location of Humidifier’s Manifold in an Air Conditioning System 4 Identify your Components 5 How to Use this M

Page 24 - Plumbing

27 | SAM-e Installation Mini SAM-e Pressurized without External Separator • Max steam pressure of 15 psig when no

Page 25 - SAM-e with Pressure Steam

SAM-e Installation | 28 Mini SAM-e Condensate Pump Plumbing When pressurized steam enters Mini SAM-e, pressure drops down

Page 26 - 23

29 | SAM-e Installation SAM-e with Atmospheric Steam Atmospheric Plumbing Atmospheric steam inlet Use Nortec supplied steam hose and gear c

Page 27 - Internal Baffle Plate

SAM-e Installation | 30 Plumbing with Drain Water Cooler 1" NPT to 3/4” NPT Reducer (Supplied By Others) 1" Air Gap To Prevent

Page 28 - 25

31 | SAM-e Installation Mini SAM-e with Atmospheric Steam Mini SAM-e with Atmospheric Steam Atmospheric steam inlet Use Nortec supplied steam ho

Page 29 - SAM-e Installation

SAM-e Installation | 32

Page 30 - 27

33 | SAM-e Installation Atmospheric Steam Lines

Page 31 - SAM-e Installation

SAM-e Installation | 34 Plumbing Pressurized SAM-e For pressurized steam line installation instructions, refer to LiveSteam Steam Injection Humidifie

Page 32 - SAM-e with Atmospheric Steam

35 | SAM-e Installation Electrode Steam-Line Table 1: Electrode Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size

Page 33 - SAM-e Installation

SAM-e Installation | 36 Gas Steam-Line Table 2: Gas Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size Stainless st

Page 34 - 8” min

1 | SAM-e Installation CAUTION: Plumbing  Plumbing to be performed by a licensed plumber.  Drain water from humidifier can be very hot. Do not

Page 35 - SAM-e Installation

37 | SAM-e Installation SE Steam Line Table 3: SE Steam-Line Unit No. of Steam Outlets Steam output [ lb ] MED-L copper tube nominal steam line siz

Page 36 - Atmospheric Steam Lines

SAM-e Installation | 38 NHRS Steam-Line Table 4: SE Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size Stainless ste

Page 37

39 | SAM-e Installation Effective Length of Typical Steam-Line Fittings Table 5: Effective length of Typical Steam-Line Fittings Nominal tube size St

Page 38 - Electrode Steam-Line

SAM-e Installation | 40 Atmospheric SAM-e Condensate Drainage 1 SAM-e condensate outlet connection is male 3/4”-NPT. 2 Condensate from SAM-e must b

Page 39 - Gas Steam-Line

41 | SAM-e Installation Steam Lines and Condensate Returns Use appropriate slope Figure 1: Slope Figure 2: Insulate pipe

Page 40 - SE Steam Line

SAM-e Installation | 42 Figure 4: Distributor Above Humidifier (Copper Steam Line) Figure 5: Distributor Above Humidifier (Hose)

Page 41

43 | SAM-e Installation Figure 6: Steam Distributor Below Humidifier (Hose) Figure 7: Steam Distributor Below Humidifier and Obstruction (Hose)

Page 42 - Material for Steam Lines

SAM-e Installation | 44 Figure 8: Long Steam Run

Page 43 - SAM-e Installation

45 | SAM-e Installation Atmospheric Steam Lines

Page 44 - Figure 3: Condensate Traps

SAM-e Installation | 46 Insulation Factory-Installed Insulation 1 Unpack tubes and headers. Inspect tubes to ensure that stainless insulation cove

Page 45

SAM-e Installation | 2 Introduction Receiving and Unpacking Equipment Check packing slip to ensure ALL material has been delivered. Each humidifi

Page 46

47 | SAM-e Installation Quantity of Insulating Covers Required to Cover SAM-e Tube Table 7: Quantity of Insulating Covers Required to Cover SAM-e Tub

Page 47

SAM-e Installation | 48 Header Installation 1 Install header insulation for SAM-e; expand header insulation to fit over header and slide on. Ensur

Page 48

49 | SAM-e Installation SAM-e Insulation Retrofit 1 Install header wrap around header. 2 Tuck header wrap underneath rubber grommets and

Page 49 - Insulation

SAM-e Installation | 50 FOR DUAL INLETS; INSULATE HEADER AS SHOWN ON PREVIOUS PAGE. INSULATE SECOND INLET AS SHOWNROLL SHIELD TO CREATE OVERLAPDETAI

Page 50

51 | SAM-e Installation 3 Apply shields to tubes and secure with stainless straps. 4 Completed Tube.

Page 51 - Header Installation

SAM-e Installation | 52 Mini SAM-e Insulation Retrofit 1 Connect Top and Bottom heat shields together (snap fit) . 2 Completed header.

Page 52 - SAM-e Insulation Retrofit

53 | SAM-e Installation 3 Fit shields to tubes. 4 Secure with stainless straps.

Page 53 - SAM-e Installation

SAM-e Installation | 54 5 Completed tube.

Page 54 - 51

55 | SAM-e Installation Troubleshooting, Maintenance, Spare Parts

Page 55 - Completed header

SAM-e Installation | 56 Troubleshooting Steam tubes discharge water: 1 Steam supply pipe is not insulated. 2 Steam supply pipe not properly drain

Page 56 - 53

3 | SAM-e Installation Identify your Components

Page 58 - Spare Parts

57 | SAM-e Installation Warranty Nortec Humidity Inc. and/or Nortec Humidity Ltd. (hereinafter collectively referred to as THE COMPANY), warran

Page 59 - Maintenance

U.S.A. 1860 Renaissance Blvd. Sturtevant, WI 53177 826 Proctor Avenue Ogdensburg, NY 13669 CANADA 2740 Fenton Road Ottawa, Ontario K1T 3T7 TEL:

Page 60

SAM-e Installation | 4 Identify your Optional Components

Page 61 - Warranty

5 | SAM-e Installation How to Use this Manual SAM-e - In Duct Section 2 Follow steps 1-9 SAM-e - Vertical Duct Installation Section 4 Foll